This lab served to make us see which strain of bacteria was more antibiotic resistant and also allowed us to see the MIC values for each bacteria tested. For my lab the results did not go too well. I used the same plates for two runs. Trial Run is found on the inside section of each plate. As one can see, only bacteria A grew while there was no visible bacterial growth for bacteria B. According to my lab results from my first trial, the MIC value for bacteria A was between 50ug/ml and 10ug/ml. Because there was no bacterial growth for bacteria B I decided to run another trial. This trial is visible on the same plate and is the subsections found on the side of the plates. Again, in this trial there was no visible bacterial growth. According to group members results, the MIC values for bacteria A should have been around 50ug/ml and 10ug/ml (what I got in trial one) and the MIC value for bacteria B should have been above 200 ug/ml. This means that bacteria B was more antibiotic resistant. Because my second trial did not go as planned either I conducted another trial but this time with a whole new set of plates. The results for that trial is still pending.
Saturday, February 28, 2015
Friday, February 27, 2015
Lab 4 Results- Jillian Yant
Lab 4 Results
Spectinomycin 0 ug/ml- 24 hours Spec. 0 ug/ml- 48 hours
Spec. 10 ug/ml- 24 hours Spec. 10 ug/ ml- 48 hours
Spec. 100 ug/ml- 24 hours Spec. 100 ug/ml- 48 hours
Spec. 200 ug/ml- 24 hours Spec. 200 ug/ml- 48 hours
Conclusions: After spotting two different strains of GC onto different dilutions of antibiotic media, we were able to determine which strain is more antibiotic resistant and a general MIC value for each strain. The MIC for strain A was between 50ug/ml and 10ug/ml. No bacteria grew on the 50ug/ml plate but it did grow on the 10 ug/ml plate. Since no bacteria grew at all we can infer that the MIC would be lower than 50. We would have to do more experiments with concentrations between 10 and 50 to determine a more accurate MIC value. The MIC value for stain B is above 200 ug/ml. Strain B is the more antibiotic resistant by far of the two strains. Even in the highest concentration of spectinomycin strain B still grew well. Even though there was contamination on my 0 ug/ml plate it was not close enough to my spotting to affect my results.
Minimum Inhibitory Concentration (MIC) Test Results - Lab #4
LAB 4 WEEK RESULTS
TIMOTHY LIU
Spec 50 ul
Spec 100 ul
Spec 200 ul
Spec 10
Spec 0
MIC Test Results:
Strain A has an MIC of spec 50.
Strain B has an MIC of over spec 200.
From this data it can be inferred that strain A is less resistant to antibiotics, while strain B possesses more powerful mechanisms to resist streptomycin.
Conclusions:
I performed the MIC test twice in order to generate conclusive results. There was minimum contamination, but there was likely an error in transferring the serial dilutions, because the amount of bacteria grown from strains A and B were not as dense as expected. The second test, which was completed on the outer later of the same petri dishes, provided more solid data.
Timothy Liu
Group 3
Lab 4 Results
| 0 ug/mL |
| 10 ug/mL |
| 50 ug/mL |
| 100 ug/mL |
| 200 ug/mL |
Thursday, February 26, 2015
Lab 4 Results
Spotting Plates that contain Spectinomycin
Tuesday, February 17, 2015
Tejah Lab 2
This weeks lab involved 3 things: making medium, by which the bacteria would grow, 4 way streaking, to see and isolate single colonies of the GC bacteria, and serial dilutions, to also isolate and see single colonies of bacteria.
This is an example of 4 way streaking. The amount of bacteria decrease until you can see single colonies of the bacteria, meaning this plate was a success. There doesn't appear to be contamination either.
This is an example of the serial dilution. The purpose is for the bacteria to become less concentrated as the GC/microliter concentration also decreases. From the 10^9 spot, to the 10^2 spot, there is a clear decrease in the concentration and a single colony can be viewed. There also doesn't appear to be contamination on this plate.
This is an example of 4 way streaking. The amount of bacteria decrease until you can see single colonies of the bacteria, meaning this plate was a success. There doesn't appear to be contamination either.
Monday, February 16, 2015
Lab 2 Results
This week we worked on creating the medium, 4 way streak bacteria to isolate colonies, and serial dilution of bacteria ranging from 10^9 to 10^2 GC/mL. I believe my serial dilution has a bit of a contamination. The main problem I had with the 4 way streaking is pushing too hard and breaking the gel. I only waited around 20 hours before checking on my colonies but I did see some growth.
Lab 2 results
This week the focus in the lab was to learn how to create the medium in which the bacteria would grow, to learn how to streak bacteria to isolate single colonies, and to learn how to dilute bacteria solutions to isolate colonies.
This technique is called four-way streaking. I started in the top right quadrant and streaked down, then went to the top left, then the bottom left to the bottom right. This plate was left sitting for about 20 hours so not all of the bacteria grew fully. The streaking however was a success because bacteria colonies did grow.
This plate demonstrates my serial dilution. The point of serial dilutions is for the bacteria to become less concentrated as the GC/microliter gets smaller. In 10^9, the bacteria is the most concentrated and you cant see single colonies. As the numbers get smaller and the solution is less concentrated, it is possible to see single colonies. I found that at 10^5 concentration there are 8 colonies. Therefore at 10^6 concentration there are 80 colonies, at 10^7 there are 800... and at 10^9 there are 80,000 GC/10 microliters or 8x10^6 GC/1000 microliters. There is a small amount of contamination on the plate but this is not from the environment or experiment, it is from the plate itself under the agar.
Sunday, February 15, 2015
Lab week 2 results
We have the four way streak and the diluted results. In the dilution where the results appear to be off it is not. I messed up the numbers and had to put the first dilution in the last one.
Lab Week 2 Results
Medium for bacteria growth:
Proof that the medium was successful (bacteria grew on plate!):
Four-Way Streaking Results
Serial Dilutions
(Serial dilution demonstrates that at a concentration of 10^8/mL single colonies can be visualized)
(Above picture denotes original serial dilution results; contamination is evident)
Subscribe to:
Posts (Atom)










