No contamination is visible on any of the plates. Both strains of A and B are seen in the concentrations 0 ug/ml and 10 ug/ml.
As you can see the MIC of strain A is between 10 ug/ml and 50 ug/ml. So another experiment would need to be conducted with intervals between 10-50 ug/ml to find a more accurate MIC for strain A.
As you can see there is no MIC of strain B seen in this experiment. Strain B continues to grow on each plate so in order to find the MIC of strain B, we would have to continue the experiment with more dilutions of spectinomycin greater than 200 ug/ml.





When you measured strain A and Strain B, were they the same Klett# ?
ReplyDeleteIf the dilution is right you should be able to see some colonies even at 1/81, and I do not see that. What do you think it might be wrong other than dilution?