Tejah Lee 54V Spectinomycin, Kanamycin, Erythromycin, Ciprofloxacin, and Chloramphenicol MIC



Spectinomycin

These are the results from the comparison between Strain A, my strain (X) and Strain B. Strain B was contaminated on all of the plates. This lets me know that contamination must have occurred anywhere between making the concentration of the bacteria for strain B and the Spotting.

Disregard strain B because it is contaminated. This is a Spec 15 plate. There is growth for both strain A and X


This is the Spec 20 plate. There is no growth for Strain X, letting me know that the MIC for my strain, for spectinomycin is 20. Since there is still growth on A, the MIC is higher than 20.





















This is the Spec 25 plate. There isn't growth for Strain A. This lets me know that the MIC for strain A is 25.



















KANAMYCIN

This is the Kanamycin 6.25 plate. There is growth for both Strains A and X, letting me know that the MIC is higher than 6.25


This is the Kanamycin 12.5 plate.  There is growth for both strains on this plate.




 This is the Kanamycin 25 plate. There isn't any growth for either of the strains and this tells me that the MIC for Strains A and X, at kanamycin, are 25.



 Erythromycin
There is no growth for Strain X on the Erythromycin 1 plate. This lets me know the MIC for X is either 1 or at a concentration lower than 1. There is growth for A.



 There isn't growth on Erythromycin plates 2,4, or 5. This lets me know that the MIC for stain A, at erythromycin is 2.






Ciprofloxacin
 The experiment for Ciprofloxacin was contaminated multiple times. This led me to believe that the plates that we were using were old. New plates were made, however there wasn't time to do the MIC test for Cipro on the new plates. Although the plates were contaminated, GC growth was still slightly visible beneath the contamination. However, that data wouldn't be good to use.

 
 
 

Chloramphenicol

Like the Cipro plates, the Chloramphenicol plates were completely contaminated. I also assumed this was due to the plates being old. New plates were made for Chloramphenicol, however there wasn't time to do a MIC test for this antibiotic on the new plates. Growth of GC was also visible underneath the contamination.